Aerosol: SOP for Aerosol Emission Rate Testing – V 2.0

Aerosol: SOP for Aerosol Emission Rate Testing – V 2.0

Procedure for Aerosol Emission Rate Testing

Department Aerosol
SOP No. SOP/Aerosol/198/2025
Supersedes SOP/Aerosol/198/2022
Page No. Page 1 of Y
Issue Date 06/02/2025
Effective Date 16/02/2025
Review Date 06/02/2028

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish a validated method for determining the emission rate of aerosol products to ensure consistent performance, product efficacy, and compliance with regulatory requirements.

2. Scope

This SOP applies to all aerosol products tested for emission rate in the Quality Control (QC) laboratory, as well as in-process testing during production.

3. Responsibilities

  • Quality Control (QC) Analysts: Responsible for conducting emission rate testing.
  • Quality Assurance (QA) Team: Responsible for reviewing and approving test results.
  • Production Team: Responsible for providing representative samples for testing.
  • Regulatory Affairs Team: Responsible for ensuring compliance with global aerosol performance standards.

4. Accountability

The Quality Control Manager is accountable for ensuring the accuracy and compliance of aerosol emission rate testing.

5. Procedure

5.1. Sample Preparation

  1. Select aerosol cans randomly from the batch.
  2. Ensure samples are conditioned at room temperature before testing.
  3. Record sample details in the Emission Rate Sample Log (Annexure-1).

5.2. Testing Setup

  1. Place the aerosol can on an analytical balance.
  2. Ensure the can is positioned vertically and secured in place.
  3. Record setup details in the Testing Setup Log (Annexure-2).

5.3. Determining Aerosol Emission Rate

  1. Record the initial weight of the aerosol can.
  2. Actuate the
spray for a fixed time (e.g., 10 seconds).
  • Weigh the can immediately after spraying.
  • Calculate the emission rate using the formula:
  • Emission Rate (g/sec) = (Initial Weight – Final Weight) / Spray Time
  • Record results in the Emission Rate Test Log (Annexure-3).
  • 5.4. Data Analysis and Acceptance Criteria

    1. Compare the measured emission rate with the product specifications.
    2. Identify any deviations from acceptable limits.
    3. Document findings in the Emission Rate Analysis Report (Annexure-4).

    5.5. Corrective Actions for Non-Conforming Results

    1. Investigate potential causes such as valve defects, propellant issues, or formulation inconsistencies.
    2. Implement corrective actions as required.
    3. Record corrective measures in the Emission Rate Corrective Action Log (Annexure-5).

    6. Abbreviations

    • GMP: Good Manufacturing Practice
    • QC: Quality Control
    • QA: Quality Assurance
    • SOP: Standard Operating Procedure

    7. Documents

    1. Emission Rate Sample Log (Annexure-1)
    2. Testing Setup Log (Annexure-2)
    3. Emission Rate Test Log (Annexure-3)
    4. Emission Rate Analysis Report (Annexure-4)
    5. Emission Rate Corrective Action Log (Annexure-5)

    8. References

    • Good Manufacturing Practice (GMP) Guidelines
    • ISO 16000-13 Standard for Aerosol Emissions Testing
    • FDA Guidance on Aerosol Product Performance

    9. SOP Version

    Version: 2.0

    10. Approval Section

    Prepared By Checked By Approved By
    Signature
    Date
    Name
    Designation
    Department

    11. Annexures

    Annexure-1: Emission Rate Sample Log

    Batch No. Sample ID Test Date Checked By
    BN-260 SPL-501 07/02/2025 QA Team

    Annexure-2: Testing Setup Log

    Sample ID Setup Details Test Method Reviewed By
    SPL-501 Secured on balance Weighing Method QA Team

    Annexure-3: Emission Rate Test Log

    Sample ID Initial Weight (g) Final Weight (g) Emission Rate (g/sec) Checked By
    SPL-501 150.2 148.5 0.17 QA Team

    Annexure-4: Emission Rate Analysis Report

    Batch No. Emission Rate (g/sec) Specification Approved By
    BN-261 0.17 0.15 – 0.20 QA Team

    Annexure-5: Emission Rate Corrective Action Log

    Issue Identified Corrective Action Implementation Date Approved By
    Emission Rate Below Limit Valve Adjustment 08/02/2025 Anjali Sharma

    12. Revision History:

    Revision Date Revision No. Revision Details Reason for Revision Approved By
    01/01/2024 V 1.0 Initial Release First Issue Anjali Sharma
    01/01/2025 V 2.0 Updated emission rate test procedure GMP Compliance Anjali Sharma