Aerosol: SOP for Validating Temperature Sensors in Aerosol Manufacturing – V 2.0

Posted on By

Aerosol: SOP for Validating Temperature Sensors in Aerosol Manufacturing – V 2.0

SOP for Validating Temperature Sensors in Aerosol Manufacturing

Department Aerosol
SOP No. SOP/Aerosol/136/2025
Supersedes SOP/Aerosol/136/2022
Page No. Page 1 of Y
Issue Date 06/02/2025
Effective Date 16/02/2025
Review Date 06/02/2028

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to provide guidelines for the validation of temperature sensors used in aerosol manufacturing. Temperature sensors are critical for monitoring and controlling temperatures during the production process, including the filling, mixing, and curing stages. This SOP ensures that temperature sensors are accurate, reliable, and calibrated according to defined standards, ensuring that product quality and safety are maintained.

2. Scope

This SOP applies to the validation of all temperature sensors used in aerosol manufacturing processes, including those used in mixers, filling machines, storage tanks, and any other temperature-sensitive equipment. The validation process includes the calibration of the temperature sensors, verification of their accuracy, and the documentation of the results.

3. Responsibilities

  • Engineering Team: Responsible for overseeing the validation process for temperature sensors, ensuring that the sensors are calibrated and functioning properly according to the defined standards.
  • Production Team: Responsible for ensuring the proper operation of the temperature sensors during the manufacturing process and reporting any discrepancies or malfunctions.
  • Quality Assurance (QA) Team: Responsible for reviewing and approving the temperature sensor validation documentation,
ensuring that the validation meets regulatory standards and GMP requirements.
  • Maintenance Team: Responsible for maintaining the temperature sensors and performing corrective actions if any issues are detected during the validation process.
  • 4. Accountability

    The Manufacturing Manager is accountable for ensuring that the temperature sensor validation process is conducted and documented in compliance with this SOP. The overall compliance with this SOP is overseen by the Quality Assurance (QA) Manager.

    5. Procedure

    5.1. Preparing for Temperature Sensor Validation

    1. Before starting the validation process, ensure that all temperature sensors are installed correctly and in their designated locations. Verify that the sensors are properly connected to the measurement system and that the system is operational.
    2. Ensure that all necessary calibration equipment is available, including calibration thermometers, standard reference materials, and temperature-controlled baths or ovens.
    3. Verify that the temperature sensors are clean and free from any contaminants or damage before conducting the validation.
    4. Review the manufacturer’s specifications for the temperature sensors to understand the required calibration methods, acceptable tolerance limits, and the performance characteristics of the sensors.
    5. Establish the validation team, which should include representatives from the Engineering, Production, and QA teams.

    5.2. Conducting the Temperature Sensor Validation

    1. Perform the following tests as part of the temperature sensor validation process:
      • Calibration Test: Use a calibrated reference thermometer or temperature calibration device to measure the temperature at several points across the sensor’s operational range. The temperature sensor readings should be compared to the reference thermometer readings to verify accuracy.
      • Accuracy Test: Test the temperature sensor by measuring known temperature standards (e.g., ice water at 0°C and boiling water at 100°C) to ensure that the sensor provides accurate readings under controlled conditions.
      • Repeatability Test: Repeat the calibration test multiple times to ensure that the sensor consistently provides the same readings under the same conditions.
      • Linear Range Test: Verify that the temperature sensor provides consistent and linear readings across its specified temperature range. Use known temperature standards to confirm the sensor’s linearity.
      • Environmental Testing: Verify that the temperature sensor operates correctly under the environmental conditions in which it will be used (e.g., ambient temperature, humidity). Ensure that the sensor’s performance is not affected by factors outside the specified operating range.
    2. Record all test results, including the test conditions, measured values, and any deviations observed. Document the calibration, accuracy, and repeatability results in the Temperature Sensor Validation Report (Annexure-1).

    5.3. Documenting the Validation Results

    1. Document the following information in the Temperature Sensor Validation Report (Annexure-1):
      • Details of the temperature sensor, including the model, serial number, and installation location
      • The reference calibration standards used for testing
      • The results of each validation test (e.g., calibration, accuracy, repeatability, linear range)
      • The name and signature of the personnel who performed the validation tests
      • The date and time of testing
    2. Ensure that the validation report is signed and approved by the responsible personnel (e.g., Engineering, Production, and QA teams).

    5.4. Reviewing and Approving the Validation Report

    1. The QA team should review the Temperature Sensor Validation Report to ensure that all tests have been conducted according to the protocol and that the sensor meets the required accuracy and performance specifications.
    2. If any deviations are observed during the validation process, they should be documented in the Deviation Log (Annexure-2), and corrective actions should be taken.
    3. The QA team should approve the report once all validation activities are complete and any deviations have been addressed.

    5.5. Finalizing the Validation Process

    1. Once the temperature sensor is validated, it is considered ready for use in the aerosol manufacturing process. The validated sensor can be used for ongoing temperature monitoring and control during production.
    2. All documentation, including the Temperature Sensor Validation Report, Deviation Log, and any corrective actions, should be archived for future audits and inspections.
    3. Periodic revalidation and calibration activities should be scheduled as per the manufacturer’s recommendations and regulatory requirements.

    6. Abbreviations

    • GMP: Good Manufacturing Practice
    • QA: Quality Assurance
    • SOP: Standard Operating Procedure
    • CAPA: Corrective and Preventive Action
    • OQ: Operational Qualification
    • PQ: Performance Qualification
    • IQ: Installation Qualification

    7. Documents

    1. Temperature Sensor Validation Report (Annexure-1)
    2. Deviation Log (Annexure-2)

    8. References

    This SOP is based on the following regulatory guidelines and industry standards:

    • Good Manufacturing Practice (GMP) Guidelines
    • FDA Code of Federal Regulations (CFR) Title 21, Part 211
    • International Council for Harmonisation (ICH) Guidelines

    9. SOP Version

    Version: 2.0

    10. Approval Section

    Prepared By Checked By Approved By
    Signature
    Date
    Name
    Designation
    Department

    11. Annexures

    Annexure-1: Temperature Sensor Validation Report

    Sensor ID Model Number Serial Number Test Date Test Type Result
    TS-001 Model X SN123456 06/02/2025 Calibration Test Pass
    TS-001 Model X SN123456 06/02/2025 Accuracy Test Pass

    Annexure-2: Deviation Log

    Deviation ID Deviation Description Corrective Action Assigned To Status
    DEV-12345 Temperature sensor inaccurate Recalibrated sensor Rajesh Patel Completed

    12. Revision History:

    Revision Date Revision No. Revision Details Reason for Revision Approved By Page No. Ref. Point No. Details of Revision
    01/01/2024 V 1.0 Initial Release First Issue Anjali Sharma Page 1 [Ref Point] First Release
    01/01/2025 V 2.0 Updated temperature validation procedures To comply with updated GMP regulations Anjali Sharma Page 1 [Ref Point] Updated procedures
    See also  Aerosol: SOP for Packing Aerosols in Secondary Packaging Materials - V 2.0
    Aerosols V 2.0 Tags:Aerosol Batch Production, Aerosol Can Design, Aerosol Cold Filling, Aerosol Documentation Standards, Aerosol Emissions Control, Aerosol Environmental Regulations, Aerosol equipment calibration, Aerosol Filling Process, Aerosol Fire Safety Measures, Aerosol Formulation, Aerosol Good Manufacturing Practice (GMP), Aerosol Hazardous Materials Handling, Aerosol Incident Reporting, Aerosol Leak Testing, Aerosol Maintenance Schedules, Aerosol Personal Protective Equipment (PPE), Aerosol Pressure Filling, Aerosol Product Labeling, Aerosol Product Testing, Aerosol Propellant Selection, Aerosol quality control, Aerosol Regulatory Compliance, Aerosol Risk Assessment, Aerosol Safety Protocols, Aerosol Standard Operating Procedures (SOPs), Aerosol Storage Requirements, Aerosol Training Programs, Aerosol Valve Crimping, Aerosol Ventilation Systems, Aerosol Waste Disposal

    Post navigation

    Previous Post: Biosimilars: SOP for Monitoring CO₂ Levels in Incubators – V 2.0
    Next Post: API Manufacturing: SOP for Real-Time Yield Monitoring During Reactions – V 2.0

    Standard Operating Procedures V 1.0

    • Aerosols
    • Analytical Method Development
    • Bioequivalence Bioavailability Study
    • Capsule Formulation
    • Clinical Studies
    • Creams
    • Data Integrity
    • Dental Dosage Forms
    • Drug Discovery
    • Environment, Health and Safety
    • Formulation Development
    • Gels
    • Good Distribution Practice
    • Good Warehousing Practices
    • In-Process Control
    • Injectables
    • Liquid Orals
    • Liposome and Emulsion Formulations
    • Lotions
    • Lyophilized Products
    • Maintenance Dept.
    • Medical Devices
    • Metered-Dose Inhaler
    • Microbiology Testing
    • Nanoparticle Formulation
    • Nasal Spray Formulations
    • Nebulizers
    • Ocular (Eye) Dosage Forms
    • Ointments
    • Otic (Ear) Dosage Forms
    • Pharmacovigilance
    • Powder & Granules
    • Purchase Departments
    • Quality Assurance
    • Quality Control
    • Raw Material Stores
    • Regulatory Affairs
    • Tablet Manufacturing
    • Rectal Dosage Forms
    • Transdermal Patches
    • Vaginal Dosage Forms
    • Validations and Qualifications

    Read SOPs in your Language:

     - 
    Bengali
     - 
    bn
    English
     - 
    en
    Gujarati
     - 
    gu
    Hindi
     - 
    hi
    Malayalam
     - 
    ml
    Marathi
     - 
    mr
    Punjabi
     - 
    pa
    Tamil
     - 
    ta
    Telugu
     - 
    te

    NEW! Revised SOPs – V 2.0

    • Aerosols V 2.0
    • Analytical Method Development V 2.0
    • API Manufacturing V 2.0
    • BA-BE Studies V 2.0
    • Biosimilars V 2.0
    • Capsules V 2.0
    • Creams V 2.0
    • Elixers V 2.0
    • Ointments V 2.0
    • Raw Material Warehouse V 2.0
    • Tablet Manufacturing V2.0

    New Publication: A must for All.

    Copyright © 2025 SOP Guide for Pharma.

    Powered by PressBook WordPress theme

    Go to mobile version