SOP for Monitoring Air Emissions During Waste Incineration

Posted on By

SOP for Monitoring Air Emissions During Waste Incineration

Standard Operating Procedure for Monitoring Air Emissions During Waste Incineration

1) Purpose

The purpose of this SOP is to establish a systematic procedure for monitoring air emissions generated during waste incineration to ensure compliance with environmental standards and minimize the release of harmful pollutants into the atmosphere.

2) Scope

This SOP applies to all waste incineration processes within the facility, including the incineration of hazardous, biomedical, and general waste. It is relevant to personnel responsible for waste management, environmental monitoring, and equipment maintenance.

3) Responsibilities

  • Environmental Officers: Oversee the air emission monitoring process and ensure compliance with regulations.
  • Incinerator Operators: Operate incinerators as per standard procedures and assist in emission monitoring activities.
  • Maintenance Personnel: Maintain emission monitoring equipment and ensure proper calibration.
  • Compliance Team: Document and report emission data to regulatory authorities as required.

4) Procedure

4.1 Regulatory Requirements and Standards

  1. Emission Limits:
    • Comply with emission standards for pollutants such as particulate matter (PM), sulfur dioxide (SO₂), nitrogen oxides (NOₓ), carbon monoxide (CO), and dioxins/furans as prescribed by local environmental authorities.
  2. less
    Copy code

  3. Guidelines:
    • Follow guidelines issued by regulatory bodies such as the EPA, CPCB, or equivalent agencies.
See also  SOP for Managing Radioactive Materials

4.2 Preparation for Emission Monitoring

  1. Inspection of Monitoring Equipment:
    • Ensure that stack monitoring systems, probes, and sampling devices are functional and calibrated.
    • Conduct pre-operation checks to verify equipment integrity and connectivity.
  2. less
    Copy code

  3. Selection of Monitoring Locations:
    • Install stack monitoring equipment at appropriate locations to capture representative emission samples.
    • Ensure that sampling ports and access points comply with regulatory specifications.

4.3 Real-Time Monitoring of Emissions

  1. Continuous Emission Monitoring System (CEMS):
    • Operate the CEMS to measure parameters such as PM, CO, SO₂, and NOₓ in real time.
    • Log data automatically into the system’s data acquisition software.
  2. less
    Copy code

  3. Manual Sampling (if applicable):
    • Use portable gas analyzers or isokinetic sampling devices to measure pollutant levels.
    • Follow standard methods (e.g., EPA Method 5 for PM, Method 23 for dioxins/furans).
See also  SOP for Inspection of Hazardous Material Storage Areas

4.4 Data Recording and Analysis

  1. Recording Emission Data:
    • Log real-time data from CEMS and manual sampling results into the Emission Monitoring Log (Annexure 1).
    • Record key parameters such as temperature, gas flow rate, and pollutant concentrations.
  2. less
    Copy code

  3. Data Analysis:
    • Compare emission levels with regulatory limits to identify non-compliance or anomalies.
    • Perform trend analysis to detect changes in emission patterns over time.

4.5 Corrective Actions

  1. Operational Adjustments:
    • Optimize incinerator temperature and air supply to minimize pollutant formation.
    • Address abnormal operating conditions (e.g., incomplete combustion or excess oxygen).
  2. less
    Copy code

  3. Maintenance of Equipment:
    • Inspect and clean incinerator components such as burners, filters, and scrubbers regularly.
    • Calibrate and maintain CEMS equipment as per manufacturer recommendations.
  4. Incident Reporting:
    • Document any exceedances or equipment malfunctions in the Emission Incident Report Log (Annexure 2).
    • Report non-compliance incidents to the regulatory authorities within the stipulated time frame.
See also  SOP for Creating and Reviewing Risk Assessment Reports

4.6 Documentation and Reporting

  1. Maintain Records:
    • Store emission monitoring logs, calibration certificates, and incident reports for a minimum of 5 years.
  2. less
    Copy code

  3. Regulatory Reporting:
    • Submit periodic emission reports to the relevant authorities, as per compliance requirements.

5) Abbreviations, if any

  • CEMS: Continuous Emission Monitoring System
  • PM: Particulate Matter
  • CO: Carbon Monoxide
  • SO₂: Sulfur Dioxide
  • NOₓ: Nitrogen Oxides

6) Documents, if any

  • Emission Monitoring Log
  • Emission Incident Report Log
  • Calibration Records
  • Regulatory Reports

7) Reference, if any

  • EPA Emission Standards
  • CPCB Guidelines for Waste Incineration
  • ISO 14001 Environmental Management Systems

8) SOP Version

Version: 1.0

Annexure

Template 1: Emission Monitoring Log

 
Date Time Parameter Measured Value Regulatory Limit Operator Name
DD/MM/YYYY HH:MM PM 10 µg/m³ 20 µg/m³ John Doe

Template 2: Emission Incident Report Log

 
Date Time Incident Description Corrective Action Taken Reported By
DD/MM/YYYY HH:MM SO₂ levels exceeded limit Adjusted temperature and air supply Jane Smith
Environment, Health and Safety Tags:Emergency response for hazardous materials incidents, Hazardous materials classification, Hazardous materials compliance audits, Hazardous materials decontamination procedures, Hazardous materials disposal methods, Hazardous materials emergency planning, Hazardous materials emergency response guidebook, Hazardous materials exposure limits, Hazardous materials handling, Hazardous materials handling equipment, Hazardous materials incident command system, Hazardous materials incident reporting, Hazardous materials inventory management, Hazardous materials labeling requirements, Hazardous materials monitoring equipment, Hazardous materials packaging requirements, Hazardous materials placarding requirements, Hazardous materials regulatory agencies, Hazardous materials response team training, Hazardous materials risk assessment, Hazardous materials security plans, Hazardous materials shipping papers, Hazardous materials spill response, Hazardous materials storage guidelines, Hazardous materials training requirements, Hazardous materials transportation regulations, Hazardous materials transportation safety, Personal protective equipment for hazardous materials, Regulatory compliance in hazardous materials management, Safety procedures for hazardous materials

Post navigation

Previous Post: Tablets: SOP for Adjusting Compression Speed in High-Speed Tablet Machines – V 2.0
Next Post: Ointments: SOP for Pilot Batch Production of Ointments – V 2.0

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

 - 
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • Analytical Method Development V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Biosimilars V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Elixers V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version